SimMan 3G – Chest scrolling

[SimMan3G-Chest-Anchors-scroll]
  • SimMan3G - Chest

    Breathing Features

Bilateral and unilateral chest rise and fall

  • There are 4 compliance settings, from normal to extremely stiff
  • There are 4 settings for airway resistance, from normal to complete occlusion
  • Normal and abnormal breath sounds
  • 5 anterior auscultation sites and 6 posterior auscultation sites NB Left side of chest plate more heart speakers
  • Unilateral, bilateral and lobar breath sounds
  • Oxygen saturation and waveform
  • Cyanosis - indicated by oral blue lights
  • SimMan3G - Chest

    Patient Monitor Features

Breathing

  • SpO2
  • Airway respiration rate (awRR)
  • End-tidal CO2 (etCO2)
  • End-tidal O2 (etO2)
  • inO2
  • Anaesthetic Agent i.e. Sevo

Circulation

  • ECG (12-lead) and heart rate (HR)
  • Pulse
  • NBP
  • ABP
  • PAP
  • C.O.

Temperatures

  • TPeri
  • Tblood
  • SimMan3G - Chest

    Pneumothorax

  • Tension pneumothorax with needle decompression can be performed at bilateral mid clavicle line, 2nd intercostal space. The pneumothorax bladders may be pierced +/-10 times, the pressure inside the bladder will drop after repeated puncturing.
  • A 22 (or smaller) gauge needle is recommended for decompression of the chest. Using a smaller gauge needle increases the longevity of the chest skin and bladders.
  • Chest Tube Insertion
  • Chest tube insertion can be simulated, and exploration and cut can be made at left or right mid-axillary line in the 4th and 5th intercostal space.
SimMan3G - Pneumothorax
Pneumothorax insertion points
Pneumothorax insertion points
Pneumothorax insertion points
Pneumothorax insertion points
  • SimMan3G - Chest

    Cardiac Features

  • Extensive ECG library, pulses from 0-220
  • Heart sounds – 4 separate speakers
  • ECG rhythm monitoring (4-connector, 3-lead ECG)
  • 12-lead ECG display
  • Pacing
  • Defibrillation and cardio version using live defibrillators

The body sounds are simulated sounds from a human body, like heart, lungs, and bowel sounds. The sounds are integrated and generated in the Patient Simulator and transferred through the integrated speakers.

  • SimMan3G - Chest

    Defibrillation

  • With live defibrillators; energy level and waveform model is registered by the Patient Simulator
  • The energy levels and number of shocks required for automatic conversion are set in each simulation Patient Case
SimMan3G - Defib Attachment
Defibrillation studs
Defibrillation studs
3 Lead ECG positions
3 Lead ECG positions