Connection
Simpad System
- Connect Link Box to Manikin Cable
- Ensure battery is connected to Link Box and charged
- Luer lock the BP tubing to Link Box (if required)
- Turn on the Link Box & Simpad
- When a connection is made between the Link Box and Simpad, the Link Box will display a solid green light on the Power LED and a solid blue light on the Wi-Fi LED
- Check the Simpad to Link Box connection by inspecting the icons on the upper right corner of the Simpad
- If a simulated patient monitor is required
- first turn on Patient Monitor PC
- click the Wi-Fi icon on the bottom right of the Windows Task Bar and ensure a connection with SimLink
- the software may start automatically at this point; if not select the LLEAP application from the Windows desktop
- click on the Patient Monitor icon
- click the appropriate Link Box listed under the Patient Simulator window
- connection with the Link Box is now established and the Patient Monitor software will appear
Filling the Thigh Air Tank
- Attach the provided air pump to the Schrader valve located laterally on the posterior of the right thigh.(Photo 8)
- Fill the air container using the air pump to120 psi.
NOTE: An over pressure release valve is included inside the thigh and will be activated at pressure above 10 Bar (150 psi).This valve has a built in reset mechanism.
- Detach air pump from the Schrader valve.